How to check a QNAP NAS for CPU stability and overheating

Original: nasutils.net/howto-cpu-stability.html. Version of 2026-11-26.

CPU Lab in StorageDiag Workbench loads the NAS processor in rounds that follow each other without pauses. A run ends by itself when the score stops changing, or after about five minutes. CPU Lab then shows the peak CPU temperature and how far the core clocks dropped, and BlackBox shows the temperatures and fan speeds over the same minutes. Together they help you judge the cooling and decide what to check next.

Topic: Memory and processor

CPU, procesor
The chip that runs the instructions of programs. It has one or more cores. On Intel and AMD, /proc/cpuinfo gives its model as model name.

This guide covers StorageDiag Workbench & Utilities and the programs built into it: CPU Lab · BlackBox

Start menu: Benchmarks › cpuhound

  1. Prepare sign in as an administrator and pick a quiet time for the NAS
  2. Run CPU Lab watch the index settle round by round
  3. Open BlackBox follow the temperature sensors and fan speeds
  4. Read the result the verdict, the peak temperature and the clock
  5. Repeat run longer, or use Lab when other processes get in the way

01 Before you start

Propose a change

CPU Lab, Pulse and BlackBox are on the Utilities desktop and monitor the NAS that StorageDiag is installed on. Sign in as an administrator: Pulse and BlackBox open only for administrators.

  • virtual machine, maszyna wirtualna
    A computer made in software, with a system of its own.
    Pick a quiet time. CPU Lab runs its test threads at real-time priority. While it runs, shares, apps and virtual machines can respond slowly or time out.
  • Stopping a run. During the first run after the window opens, the button in the title bar reads Running and is greyed out. Later runs in the same window stop with Stop. Closing the window ends a run started with Run, the first one too. A Lab run keeps going (section 06).
  • Publishing. By default, CPU Lab publishes a result with the verdict clean or throttled on the public CPU board, with the NAS model, the processor and the memory. To keep your runs off the board, open Compare and untick publish automatically, then close CPU Lab and open it again before you click Run. The browser keeps this choice, so untick it in every browser you use. A Lab run (section 06) publishes these two verdicts in every case.
  • Greyed-out Run and Lab. When the StorageDiag daemon runs at the Safe mode or Locked down level, Run and Lab are greyed out and the window shows a notice. An administrator changes the level in Access management, on the Daemon tab.
  • History needs no setup. From the moment the package starts, BlackBox records the state of the NAS every 20 seconds, and temperatures and fan speeds once a minute.

02 Run the test

Propose a change

  1. Open CPU Lab: Start menu → Benchmarks → cpuhound, or click the desktop icon of the same name. The Processor card shows the CPU model, the number of threads, the maximum clock speed and the frequency governor.
  2. Click Run in the title bar. Each round runs the compute tests one after another, each first on one thread and then on all logical CPUs the test uses. The table lists the eight tests that make up the index. Rounds follow without pauses. The run ends when the last four rounds agree within 1.5 %, when five rounds in a row bring no tighter spread, or after about five minutes.
  3. After each round, watch the CPH index and the status line with the round number and the spread (round 8 · ±8.6 % → ±1.5 %). The table highlights the test in progress, and the Data computing card draws one tile per logical CPU.
CPU Lab during a run: round 8, CPH index 7 501, spread 8.6 percent against a target of 1.5, the branch test lit in the kernel table and every logical CPU tile busy
Figure 1. CPU Lab during a run (values from a recorded run). Round 8 on a NAS with a 12-thread Core i5-1235U. The index is still moving: the status line shows the spread of the last rounds against the 1.5 % target.
kernel, jądro
The part of Linux that manages the hardware, memory and processes.

In the table, a red Wait cell marks a test that waited for the CPU for more than 5 % of its running time. During the run, a rose contended chip on the Data computing card means that an all-core test waited that long. With the default real-time scheduler settings, the kernel keeps about 5 % of every second for other tasks, so these marks are common. The contended verdict needs more: the median wait of the last four rounds above about 10 %. The run in figure 1 ended as throttled (figure 3).

When the processor lowers its clock as it heats up, the index falls over the first rounds and then levels off. In the run in figure 1, round 1 scored 9 762, and from round 6 on the scores stayed between 7 160 and 7 808. The settled score is the performance this NAS keeps with its own cooling, in the conditions of the test.

On a NAS with four logical CPUs or fewer, CPU Lab leaves one CPU to the system. After the run, its tile turns dark (the legend says dark = left to the OS), and the NAS's total CPU load stays below 100 %.

03 Watch temperatures and fan speeds

Propose a change

CPU Lab shows the temperature only when the run ends. BlackBox records sensor readings and fan speeds all the time, so you can open it beside CPU Lab during the run or after it:

The temperatures in this section come from the program built into StorageDiag Workbench & Utilities: BlackBox

Start menu: Monitoring › BlackBox

  1. Open BlackBox: Start menu → Monitoring → BlackBox.
  2. In the title bar, choose Charts, the 1h range and the Absolute scale. On this scale the temperature and fan-speed axes start at zero.
  3. For temperatures alone, click Temp in the title bar: one panel with up to twelve sensors.
  4. For temperatures, fans and CPU load together, as in figure 2, use the series picker instead. Open it with the tab at the left edge. In the Thermal group, tick the Temperature row and click Fan speed (a NAS with several fans has a button for each). In the CPU group, click sys in the CPU busy row. Each unit (°C, rpm, %) gets its own panel on a shared time axis. A choice in the picker replaces the Temp view.
BlackBox, Charts, last hour, absolute scale: the package and four core temperatures rise from about 45 to about 76 degrees Celsius during three CPU Lab runs and level off, the system sensor moves from 36 to 41 degrees, the fan speeds up from about 1150 to 1900 rpm, and CPU busy shows three plateaus at 100 percent
Figure 2. BlackBox during three CPU Lab runs (example data from a NAS with a four-core, eight-thread CPU). The package and core sensors climb to about 76 °C and level off. The enclosure sensor system1 rises by a few degrees, and the fan speeds up as the temperature rises.
  • Sensors. Intel CPUs report package and a sensor for each core, such as core0. AMD CPUs report tctl. On models with CCD sensors, they also report tccd1, tccd2 and so on, one sensor per chiplet (a die with a group of cores). When the kernel exposes no processor sensor, the CPU temperature that QNAP reports appears as cpu. system1 and similar names are QNAP's enclosure sensors. Other devices, such as a network card, can add sensors of their own. Fans are named by number; a CPU fan is cpu1.
  • One point a minute. BlackBox reads temperatures and fan speeds once a minute, so a run of a few minutes gives only a few points. Section 05 shows how to keep the load on for longer.
  • Heat map. Heat map in the title bar draws each sensor as a row of coloured cells: amber from 65 °C, red from 80 °C.
  • Events. BlackBox marks Critical temperature on the timeline when a sensor reaches its limit. For CPU sensors, BlackBox uses the limit the CPU reports (100 °C on the Intel CPUs measured). Without a usable CPU limit, BlackBox uses 90 °C, including for QNAP's cpu reading (when the kernel exposes no CPU sensor) and AMD's tctl, tdie, tccd1, tccd2 and other CCD sensors. The limit is 60 °C for enclosure sensors, 100 °C for network-card sensors and 85 °C for all other sensors. BlackBox marks Fan stopped when a fan that QNAP reports as present reads 0 rpm. BlackBox also sends notices for these events to the QTS system log.
  • Live clock speeds. Pulse (Start menu → Monitoring → Pulse, CPU tab) refreshes every logical CPU every two seconds: Busy, Current clock (⚡ above the base clock), Min, Max and Governor. A large clock drop under steady load can point to a performance limit. Judge it together with the temperature and the governor.
  • throttling, dławienie
    Lowering of the CPU clock because of heat or a power limit.
    firmware, oprogramowanie sprzętowe
    QNAP's word for the system of the NAS, QTS or QuTS hero. It updates automatically or from an image you upload; the NAS restarts to finish the update.
    Kernel log. Start menu → Live logs → Kernel Log · LIVE opens the window of that name, which shows new kernel messages as they arrive. On Intel, if thermal throttling lasts and the CPU keeps getting hotter, the kernel writes a line such as CPU0: Package temperature is above threshold, cpu clock is throttled (total events = 12). When the temperature and speed return to normal, it writes CPU0: Package temperature/speed normal (total events = 12). StorageDiag's Kernel Log marks the throttling line as "CPU Thermal Throttle". On AMD CPUs, the kernel writes neither message. A [Hardware Error] line is a hardware error reported by the processor or the firmware, usually a machine check. Decode it in MCE Decoder (Start menu → Analysis).

04 Read the result

Propose a change

When the run ends, the CPH index card shows the verdict and the number of rounds. The Processor card gets a Thermal line: the peak CPU temperature and the lowest clock any core dropped to, as a percentage of that core's own peak. Both come from the last round.

CPU Lab after the run: verdict throttled after 14 rounds, CPH index 7 589 with precision plus or minus 5.2 percent, Thermal 98 degrees Celsius peak and clock 90 percent, the die drawn with an amber outline, and the full kernel table
Figure 3. The result of the run in figure 1. throttled · 14 rounds, index 7 589 (±5.2 %) and Thermal: 98 °C peak · clock 90 %. The processor went past CPU Lab's 95 °C threshold, and its slowest core kept 90 % of its own peak clock. The result was published, so the card shows its place on the board.
CPU Lab's verdicts
VerdictWhat happenedOn the board
cleanEvery core kept at least 90 % of its own peak clock, the CPU stayed below 95 °C, and the wait for CPU time stayed below the contended threshold.yes
throttledA core's clock fell more than 10 % below its own peak, or the hottest CPU sensor reached 95 °C. The score is the CPU's performance in that state.yes
contendedOther processes held the CPU, so the test waited for CPU time. The score is a lower bound.no
untrustedOther processes held the CPU while the clock was also dropping or the CPU had reached 95 °C.no
indicativeThe score did not settle: the spread of even the four best-agreeing consecutive rounds stayed above ±5 %. Only a run that would otherwise be clean gets this verdict.no
kernel log, log jądra
The record of events that the Linux kernel writes.

CPU Lab uses a fixed threshold of 95 °C. For CPU sensors, BlackBox uses the limit the CPU reports or 90 °C if there is no usable limit (section 03). For the weekly temperature finding, BlackBox settings offer only a warning level. The real limit depends on the processor model and the NAS design, so a reading of 85, 90 or 95 °C alone does not prove overheating. Compare the temperature with the specifications of the CPU and the NAS, with the clock speed and with the kernel log.

  • Heat or a clock limit. A throttled verdict comes from heat or from a clock drop. With a peak above 90 °C, as in figure 3, check the cooling and compare the peak with the processor's specifications. A clock drop with a peak in the 60s or 70s can point to a power limit or the governor.
  • Check the temperature on a clean run too. clean allows a peak below 95 °C. If the CPU reports no usable limit, a reading of 90 °C reaches the sensor's limit and triggers Critical temperature. CPU Lab can still rate the run as clean.
  • The CPU drawing. On the Data computing card, an amber outline means throttling and a rose outline means waiting for CPU time; the legend under the drawing names each state. The Wait column turns red above 5 %. With the default real-time scheduler settings, part of that wait can be the kernel's own reserve (section 02).
  • Index. The CPH index gives a single-thread score and an all-core score. On this scale, one thread of a current mid-range NAS processor scores about 1 000. The ring beside the index shows the precision the run reports.

05 Load the CPU for longer

Propose a change

A run lasts from about one to five minutes, and with good cooling the score can settle in four to six rounds. To watch the temperatures for longer, start each run as soon as the previous one ends:

  1. When the verdict appears on the CPH index card, click Run again. On a NAS that heats up, three runs can take about a quarter of an hour, as in figure 2. If the score settles quickly, repeat the test until BlackBox shows ten minutes of load.
  2. Watch BlackBox. With good cooling, the CPU temperatures level off and the fan holds a higher speed. If the temperatures are still rising at the end of the last run, the NAS has not reached a steady temperature yet. Check whether the clock is dropping or the model's temperature limits are exceeded.
  3. Open Compare, then the This unit tab. It lists the last 40 runs of this NAS with the date, the type (Run or Lab), the verdict and the index. Click a run to compare its all-core results, test by test, with the newest other run of the same build of CPU Lab's test program. A run of another build carries the tag other build. Similar scores across runs mean steady performance under the test conditions. Falling scores with rising temperatures call for a cooling check.

06 Test with services stopped (Lab)

Propose a change

A contended or untrusted verdict means that other processes took CPU time from the test. Lab runs the same test with the services stopped:

  1. QuTS hero
    QNAP's NAS system on ZFS.
    Close every QTS or QuTS hero tab in the browser: an open panel can start services again.
  2. iSCSI
    A protocol that gives a computer a disk of the NAS over the network as a block device.
    App Center
    The app store of QTS and QuTS hero.
    Click Lab. The panel lists the steps, the data the run writes, how long it takes and the checks. It also names what stops: file sharing, an iSCSI target, App Center packages, scheduled jobs, media, snapshots, replication and antivirus. StorageDiag, the admin panel and helpdesk keep running.
  3. degraded, zdegradowany
    The state of a RAID that works without one or more of its drives.
    scrubbing, czyszczenie RAID
    A read of a whole RAID or ZFS pool that checks redundant data and repairs what it can.
    Lab does not start while a virtual machine runs, an iSCSI session is connected, an array or pool is degraded, rebuilding, resyncing or scrubbing, or another CPU or memory test is running. A check that fails turns red and gives the reason.
  4. Tick the confirmation box and click Start Lab run.
CPU Lab with the Lab run panel: eight steps from reading the governor to showing the score, the services that will stop, the files it writes, how long it takes, five passed checks, a warning to close QTS tabs, the confirmation checkbox and the Start Lab run button
Figure 4. The Lab panel before a run (example services and checks). Estimated time: one to three minutes to stop the services (at most 30 minutes), up to five minutes for the test, and one to three minutes to start the services again.

Lab sets the governor to performance, stops the services and waits 30 seconds for the CPU to settle. Then it runs the same test, puts the previous governor back and starts the services again. A Lab run keeps going on the NAS after you close the browser. Cancel ends the test and starts the services again. When the run ends, check that your shares and apps work again.

07 Symptoms and what to do

Propose a change

What CPU Lab and BlackBox show, and what to do
What you seeWhat it meansWhat to do
clean, a peak well below 90 °C, steady temperatures and a fan holding a higher speedThe cooling copes with the load of this test.Keep the result for later comparisons.
throttled with a peak of 95 °C or more and the fans at high speedThe CPU reached CPU Lab's temperature threshold. The clock figure shows the clock it kept.Compare the temperature with the model's limits and check the cooling (section 08). Repeat the test after you fix a problem.
throttled with a peak in the 60s or 70sA power limit or the governor may be lowering the CPU's clock.Check Governor in Pulse. Lab runs with performance.
A fan at 0 rpm, or Fan stoppedA possible fault in the fan, its connection or the speed reading.Stop the test (section 01). Check that the fan turns and is connected properly. Replace it if it is faulty.
A fan that does not speed up under loadThe fan settings or the fan itself need checking.Raise the fan speed (section 08). If the fan does not respond, check it before you replace it.
Critical temperature comes back after cleaning, at a normal room temperatureA possible cooling fault, such as a worn fan or poor heatsink contact.Check the model's temperature limits. If the symptoms point to a cooling fault, take the NAS to a repair service.
The NAS restarts during a run or still does not respond after itThe cause needs more diagnosis: the power supply, motherboard, CPU, memory and temperature are all candidates.Read the kernel log and BlackBox and test the RAM, then report the problem to a repair service with these results.
[Hardware Error] lines in the kernel log during the runThe processor or the firmware reported hardware errors.Decode the lines in MCE Decoder, which names the subsystem (memory, CPU or bus), and send the result to a repair service.
contendedOther processes took the CPU time the test needed.Repeat the test with Lab (section 06).

CPU Lab does not stop when the temperature rises: it goes on measuring at the lower clock. The processor has its own thermal protection, but do not keep testing once you know the cooling has a problem. If BlackBox shows Fan stopped or 0 rpm, stop the run with Stop (a Lab run with Cancel; during the first run, close the CPU Lab window) and start no other until you have checked the fan. If the NAS hangs, find the cause before you test again.

CPU Lab measures performance and does not check the results of its calculations, so a steady index does not prove that the processor works correctly. Calculation errors can come with application crashes, restarts and machine checks, so read the kernel log too. Faulty memory causes similar symptoms: test the RAM before you suspect the processor.

08 Cool a NAS that runs hot

Propose a change

  • Dust. Remove dust from the heatsink, the fans and the air intakes.
  • Fans. Check that they run and speed up under load (BlackBox, Fan speed). If they stay slow while the CPU is hot, raise their speed in the Smart Fan settings of QTS or QuTS hero: Control Panel → System → Hardware → Smart Fan.
  • Airflow. Leave space in front of the intakes and behind the exhaust. Keep the NAS out of closed cabinets and away from other hot equipment. Lower the room temperature if you can.
  • Heatsink. Leave reseating the heatsink or replacing its thermal paste to a repair service or someone experienced in servicing NAS units.
  • Retest. After each change, repeat section 05 and compare the peak temperature, the fan speed and the index with the earlier runs.

09 Why QTS shows a lower CPU temperature

Propose a change

To check individual sensor readings at the time of a notice, use BlackBox. For the current CPU temperature, use QTS or QuTS hero. On a NAS with an Intel CPU, the smoothed reading for the whole CPU can differ from the hottest core's reading by about 20 °C. After a job ends, QTS can show a lower temperature. BlackBox keeps the reading from when the CPU was under load.

CPU temperature in QTS or QuTS hero and BlackBox
WhereWhat it readsHow oftenWhat you see
QTS or QuTS heroQNAP's CPU reading (CPUT_1)About once a secondOne current CPU value. On Intel, it is close to the average across cores.
BlackBoxTemperatures from the kernel's sensors and QNAP's enclosure sensors. If the kernel exposes no CPU sensor, BlackBox uses QNAP's CPU reading as cpu.Once a minuteA history for each sensor. BlackBox keeps the minimum, average and peak of the readings in its summaries.

On Intel, package measures the processor package and core0 measures the first physical core. On AMD, tctl is the value the system uses to control cooling. A CCD sensor such as tccd1 measures one chiplet: the die that holds a group of cores.

In one 30-second sample on an Intel NAS, QTS shows at most 51 °C and the hottest core reaches 72 °C.

To find the CPU model, run grep -m1 "model name" /proc/cpuinfo. On Intel, TjMax is the maximum junction temperature. Run cat /sys/class/hwmon/hwmon*/temp*_crit to read the limits. For TjMax, use only the values from a directory whose name file says coretemp. The files give the values in thousandths of a degree Celsius. BlackBox uses TjMax as the "Critical temperature" limit for those CPU sensors.

For AMD, look up Tjmax on AMD's product page for the CPU. AMD lists 95 °C for the Ryzen 7 3700X and for the Ryzen 5 7600 and Ryzen 7 7700 in the Ryzen 7000 series. The Ryzen Embedded V1500B has a maximum junction temperature of 105 °C. The k10temp driver reports no limit on these CPUs, so BlackBox sets the limit to 90 °C, below the listed Tjmax values.

When the CPU reaches a temperature, power or current limit, it can lower its clock to keep working. If the CPU is hot and under load, check for a clock drop in the Pulse CPU tab (section 03). A low clock at idle saves power. After a CPU Lab run, check the verdict and the Thermal line (section 04). The VM performance guide explains the weekly CPU thermal throttling finding. For cooling tips, see section 08.

10 BlackBox messages in the system log

Propose a change

  • Critical temperature. [BLACKBOX] Critical temperature - tccd1: 91 °C is an Error in the system log. That is 1 °C above the 90 °C limit BlackBox uses for tccd1. See section 03 for the other limits. BlackBox sends this notice at most once per sensor per 24 hours. The 90 °C limit is below the listed Tjmax values for Ryzen. Use the time in the log to see what job runs on the NAS. Look for dust and check the fans. Check the room temperature too. If notices recur at idle or readings approach the CPU's own limit, suspect a cooling problem.
  • Fan stopped. [BLACKBOX] Fan stopped - cpu1: cpu1 means QTS reports the fan cpu1 as present and its speed reads 0 rpm. If a test is running, stop it. Check whether the fan spins (see section 07).
  • shared folder, folder udostępniony
    A folder of a volume that users open over the network.
    Weekly report ready. [BlackBox] Weekly report ready: 1 critical, 3 warning — worst: ZFS write throttle. report-blackbox-20261109-060000.md in Public. Open the file in the Public shared folder or in StorageDiag's Reports. By default, BlackBox generates the report on Monday at 06:00 NAS time. To change the day or hour, open BlackBox settings. The numbers count critical findings and warnings. If the report has a critical finding, Worst names the first one in report order. Otherwise it names the first finding in the report. The weekly Temperatures finding uses five-minute averages to check for warnings. A sensor gets a warning if its average stays at or above the warning level for at least 10 minutes. The default warning level is 80 °C. An administrator can change it in BlackBox settings. For sensors whose names start with system, the warning level is 55 °C. For names starting with eth or en, it is 95 °C. The finding is critical only if BlackBox records a Critical temperature event for a sensor that week. The same event appears on the timeline (section 03) and can trigger a QTS notice. If the event's reading exceeds the highest five-minute average for that sensor, the report quotes the reading from the event. With the default settings and no critical temperature event that week, a tccd1 average of 85–87 °C for 10 minutes gets a warning. See the VM performance guide for findings such as ZFS write throttle.

Other notices include NAS restarted, Network link renegotiated its speed, Network link down, Process killed: out of memory, RAID array degraded, Running on battery - mains lost and Disk removed or lost.